Journal article

Sensor Concept Based on Piezoelectric PVDF Films for the Structural Health Monitoring of Fatigue Crack Growth



Publication Details
Authors:
Bäcker, D.; Ricoeur, A.; Kuna, M.

Publication year:
2011
Journal:
Structural Durability & Health Monitoring
Pages range :
1-22
Volume number:
7
Issue number:
1
ISSN:
1930-2983
eISSN:
1930-2991
DOI-Link der Erstveröffentlichung:


Abstract


A new sensor concept for monitoring fatigue crack growth in technical structures is presented. It allows the in-situ determination of the position of the crack tip as well as the fracture mechanical quantities. The required data are obtained from a piezoelectric polymer film, which is attached to the surface of the monitored structure. The stress intensity factors and the crack tip position are calculated from electrical potentials obtained from a sensor array by solving the non-linear inverse problem.




Keywords
fatigue crack growth, fracture mechanical sensor, PVDF, SIF sensor, stress intensity factors, structural health monitoring